The ElectricalSystem type exposes the following members.
Properties
| Name | Description | |
|---|---|---|
| ApparentCurrent |
The ApparentCurrent value of the Electrical System.
| |
| ApparentCurrentPhaseA |
The ApparentCurrentPhaseA value of the Electrical System.
| |
| ApparentCurrentPhaseB |
The ApparentCurrentPhaseB value of the Electrical System.
| |
| ApparentCurrentPhaseC |
The ApparentCurrentPhaseC value of the Electrical System.
| |
| ApparentLoad |
The ApparentLoad value of the Electrical System.
| |
| ApparentLoadPhaseA |
The ApparentLoadPhaseA value of the Electrical System.
| |
| ApparentLoadPhaseB |
The ApparentLoadPhaseB value of the Electrical System.
| |
| ApparentLoadPhaseC |
The ApparentLoadPhaseC value of the Electrical System.
| |
| AssemblyInstanceId |
The id of the assembly instance to which the element belongs.
(Inherited from Element.) | |
| BalancedLoad |
Reports whether the BalancedLoad is on or off.
| |
| BaseEquipment | The base panel or equipment of the system. (Inherited from MEPSystem.) | |
| BaseEquipmentConnector | The connector within base equipment which is used to connect with system. (Inherited from MEPSystem.) | |
| BoundingBox | Retrieves a box that circumscribes all geometry of the element. (Inherited from Element.) | |
| Category | Retrieves a Category object that represents the category or sub category in which the
element resides. (Inherited from Element.) | |
| CircuitConnectionType |
The circuit connection type of the electrical system.
| |
| CircuitNamingIndex |
The Circuit Naming Index where the Electrical System is located in its panel.
The Circuit Naming Index is used to retrieve the Circuit Naming Index of the Electrical System.
| |
| CircuitNumber |
The CircuitNumber of the Electrical System.
| |
| CircuitPathMode |
The circuit path mode of the electrical system.
| |
| CircuitType |
The circuit type of the Electrical System.
| |
| ConnectorManager | Connector manager of the system. (Inherited from MEPSystem.) | |
| CreatedPhaseId |
Id of a Phase at which the Element was created.
(Inherited from Element.) | |
| DemolishedPhaseId |
Id of a Phase at which the Element was demolished.
(Inherited from Element.) | |
| DesignOption | Returns the design option to which the element belongs. (Inherited from Element.) | |
| Document | Returns the Document in which the Element resides. (Inherited from Element.) | |
| Elements | Terminal elements in the system. (Inherited from MEPSystem.) | |
| Frame |
The Frame value of the Electrical System.
| |
| Geometry | Retrieves the geometric representation of the element. (Inherited from Element.) | |
| GroundConductorsNumber |
The GroundConductors Number of the Electrical System.
| |
| GroupId |
The id of the group to which an element belongs.
(Inherited from Element.) | |
| HasCustomCircuitPath |
Checks whether the electrical system circuit path has been customized. If not, the property CircuitPathMode cannot be set as Custom explicitly.
| |
| HasDesignParts |
Indicates if the system has one or more design parts.
(Inherited from MEPSystem.) | |
| HasFabricationParts |
Indicates if the system has one or more fabrication parts.
(Inherited from MEPSystem.) | |
| HasPathOffset |
Whether the circuit path has a valid offset.
| |
| HasPlaceholders |
Indicates if the system has one or more placeholders.
(Inherited from MEPSystem.) | |
| HotConductorsNumber |
The HotConductors Number of the Electrical System.
| |
| Id |
A unique identifier for an Element in an Autodesk Revit project.
(Inherited from Element.) | |
| IsBasePanelFeedThroughLugsOccupied |
Checks if the feed through lugs of the base panel is already occupied.
| |
| IsEmpty |
Indicates if the system is empty or not.
(Inherited from MEPSystem.) | |
| IsMultipleNetwork |
Indicates if the system is well connected or not. The flag will enable the "Divide System" button.
(Inherited from MEPSystem.) | |
| IsTransient |
Indicates whether an element is transient or permanent.
(Inherited from Element.) | |
| IsValid |
Indicates if the system is valid or not.
atom AtomValidateSystem
default false
(Inherited from MEPSystem.) | |
| IsValidObject |
Specifies whether the .NET object represents a valid Revit entity.
(Inherited from Element.) | |
| Length |
The Length value of the Electrical System.
| |
| LevelId |
The id of the level associated with the element.
(Inherited from Element.) | |
| LoadClassificationAbbreviations |
The LoadClassification Abbreviations used in the Electrical System.
| |
| LoadClassifications |
The LoadClassifications used in the Electrical System.
| |
| LoadName |
The LoadName of the Electrical System.
| |
| Location | This property is used to find the physical location of an element within a project. (Inherited from Element.) | |
| Name | A human readable name for the Element. (Inherited from Element.) | |
| NeutralConductorsNumber |
The NeutralConductors Number of the Electrical System.
| |
| OwnerViewId |
The id of the view that owns the element.
(Inherited from Element.) | |
| PanelName |
The Panel name of the Electrical System.
| |
| Parameter[([( Guid])]) | Retrieves a parameter from the element given a GUID for a shared parameter. (Inherited from Element.) | |
| Parameter[([( BuiltInParameter])]) | Retrieves a parameter from the element given a parameter id. (Inherited from Element.) | |
| Parameter[([( Definition])]) | Retrieves a parameter from the element based on its definition. (Inherited from Element.) | |
| Parameters | Retrieves a set containing all of the parameters that are contained within the element. (Inherited from Element.) | |
| ParametersMap | Retrieves a map containing all of the parameters that are contained within the element. (Inherited from Element.) | |
| PathOffset |
The offset of the horizontal segments of the circuit path.
| |
| PhaseLabel |
The circuit phase label used in the Electrical System.
| |
| Pinned |
Identifies if the element has been pinned to prevent changes.
(Inherited from Element.) | |
| PolesNumber |
The Poles Number of the Electrical System.
| |
| PowerFactor |
The PowerFactor value of the Electrical System.
| |
| PowerFactorState |
The PowerFactorState type of the Electrical System.
| |
| PressureLossOfCriticalPath |
The total pressure loss of the sections in critical path.
(Inherited from MEPSystem.) | |
| Rating |
The Rating value of the Electrical System.
| |
| RunsNumber |
The Runs Number of the Electrical System.
| |
| SectionsCount |
The number of sections.
(Inherited from MEPSystem.) | |
| SlotIndex |
The Slots where the Electrical System is located in its panel.
| |
| StartSlot |
The Start Slot where the Electrical System is located in its panel.
| |
| SystemType |
The Electrical System Type of the Electrical System.
| |
| TrueCurrent |
The TrueCurrent value of the Electrical System.
| |
| TrueCurrentPhaseA |
The TrueCurrentPhaseA value of the Electrical System.
| |
| TrueCurrentPhaseB |
The TrueCurrentPhaseB value of the Electrical System.
| |
| TrueCurrentPhaseC |
The TrueCurrentPhaseC value of the Electrical System.
| |
| TrueLoad |
The TrueLoad value of the Electrical System.
| |
| TrueLoadPhaseA |
The TrueLoadPhaseA value of the Electrical System.
| |
| TrueLoadPhaseB |
The TrueLoadPhaseB value of the Electrical System.
| |
| TrueLoadPhaseC |
The TrueLoadPhaseC value of the Electrical System.
| |
| UniqueId |
A stable unique identifier for an element within the document.
(Inherited from Element.) | |
| VersionGuid |
Get the element version Guid.
(Inherited from Element.) | |
| ViewSpecific |
Identifies if the element is owned by a view.
(Inherited from Element.) | |
| Voltage |
The Voltage value of the Electrical System.
| |
| VoltageDrop |
The VoltageDrop value of the Electrical System.
| |
| Ways |
The circuit ways used in the Electrical System.
| |
| WireSizeString |
The WireSize as a String of the Electrical System
| |
| WireType |
The wire type of the Electrical System.
| |
| WorksetId |
Get Id of the Workset which owns the element.
(Inherited from Element.) |