Zone |
The ZoneEquipmentData type exposes the following members.
Name | Description | |
---|---|---|
![]() | AirSystemId | The air system used for this zone equipment, if applicable. |
![]() | ChilledWaterLoopId | The chilled water loop used for the chilled water option of cooling coil. |
![]() | CondenserWaterLoopId | The condenser water loop used for the direction expansion water cooled option of cooling coil. |
![]() | CoolingCoilType | The type of cooling coil. Note this property change would reset the chilled water loop. |
![]() | EquipmentBehavior | The behavior of how zone equipment is allocated with assigned spaces. |
![]() | EquipmentType | The type of zone equipment. Note this property would reset other properties. |
![]() | HeatingCoilType | The type of heating coil. Note this property change would reset the hot water loop. |
![]() | HotWaterLoopId | The water loop element id for the hot-water heating coil. |
![]() | IsValidObject | Specifies whether the .NET object represents a valid Revit entity. |
![]() | VRFLoopId | The Varible Refrigerant Flow loop for the VRF fan coil equipment type. |
Name | Description | |
---|---|---|
![]() | Dispose | Releases all resources used by the ZoneEquipmentData |
![]() | Equals | Determines whether the specified object is equal to the current object. (Inherited from Object) |
![]() | GetHashCode | Serves as the default hash function. (Inherited from Object) |
![]() | GetType | Gets the Type of the current instance. (Inherited from Object) |
![]() | IsDataCompleted | Is the required data completed for this zone equipment? |
![]() | ToString | Returns a string that represents the current object. (Inherited from Object) |