AnalyticalPowerDistributableNodeDataDistributionSystem Property |
The distribution system of the power distributable node.
Namespace: Autodesk.Revit.DB.ElectricalAssembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntaxpublic ElementId DistributionSystem { get; set; }
Public Property DistributionSystem As ElementId
Get
Set
public:
property ElementId^ DistributionSystem {
ElementId^ get ();
void set (ElementId^ value);
}
member DistributionSystem : ElementId with get, set
Property Value
ElementId
ExceptionsException | Condition |
---|
ArgumentException |
When setting this property: The id isn't a distribution system id.
-or-
When setting this property: The distribution system id can't be set to the power distributable node.
|
ArgumentNullException |
When setting this property: A non-optional argument was null
|
Remarks
In the case of a transformer, it's crucial that the number of phases in the secondary distribution system matches
that of the primary distribution system. If the number of phases in the primary system is set to be different from
that of the secondary distribution system, it will result in a 'PrimaryNumOfPhasesNotEqualWithSecondary' error.
If you anticipate this discrepancy, you can avoid the error by first setting the secondary distribution system to InvalidElementId,
and then setting the primary distribution system.