The number of times the volume of air interchanges in the room in one hour.
Namespace: Autodesk.Revit.DB.AnalysisAssembly: RevitAPI (in RevitAPI.dll) Version: 21.0.0.0 (21.1.1.109)
Since: 2011
Syntax
C# |
---|
public double OutsideAirChangesRatePerHour { get; set; } |
Visual Basic |
---|
Public Property OutsideAirChangesRatePerHour As Double Get Set |
Visual C++ |
---|
public: property double OutsideAirChangesRatePerHour { double get (); void set (double value); } |
Remarks
Air Changes per hour is "unitless". It is a number.
It is the number of times the air (the volume) interchanges in the room in one hour.
This number is a format for expressing the requirement for airflow.
The "flow" requirement for a room might be expressed, e.g.,
one room of 100 CF, and 3 Air Changes per Hour (ACH), would compute to 100 CF x 3 ACH / 60 min = 5 CFM.
Exceptions
Exception | Condition |
---|---|
Autodesk.Revit.Exceptions..::..ArgumentOutOfRangeException | When setting this property: The outside airChangesRatePerHour does not fall within an appropriate range. |