SizingCalculatorCalculateSizeByFriction Method

Calculates the duct or pipe size based on the specified flow and friction.

Namespace: Autodesk.Revit.DB.Analysis
Assembly: RevitAPI (in RevitAPI.dll) Version: 27.0.4.0 (27.0.4.0)
Syntax
public void CalculateSizeByFriction(
	double flow,
	double friction,
	SizingOptions sizingOptions
)

Parameters

flow  Double
The flow rate.
friction  Double
The desired friction.
sizingOptions  SizingOptions
The sizing options containing other input sizing parameters (such as density, viscosity, roughness, etc.) and output sizes.
Exceptions
ExceptionCondition
ArgumentException The input must be initialized correctly for sizing operation.
ArgumentNullException A non-optional argument was null
ArgumentOutOfRangeException The given value for flow must be positive. -or- The given value for friction must be positive.
InvalidOperationException Failed to calculate the size to satisfy the friction constraint.
See Also