RebarBarTypeSetAutoCalculatedStaggerLength Method

Sets if the stagger length is auto calculated or not for the specified Rebar Splice Type.

Namespace: Autodesk.Revit.DB.Structure
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public void SetAutoCalculatedStaggerLength(
	ElementId rebarSpliceTypeId,
	bool autoCalculated
)

Parameters

rebarSpliceTypeId  ElementId
The Rebar Splice Type id. Interactions with Rebar Splice Types can be done with the functions in RebarSpliceTypeUtils.
autoCalculated  Boolean
True, if the stagger length is auto calculated, false otherwise.
Exceptions
ExceptionCondition
ArgumentException The rebarSpliceTypeId doesn't represent a valid Rebar Splice Type. It should be an ElementType of BuiltInCategory.OST_RebarSpliceType category.
ArgumentNullException A non-optional argument was null
Remarks
If it is auto calculated, stagger length value is computed based on the formula: stagger length multiplier (found in splice type) * lap length.