ViewSectionCreateReferenceSection Method |
Creates a new reference section.
Namespace: Autodesk.Revit.DBAssembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntaxpublic static void CreateReferenceSection(
Document document,
ElementId parentViewId,
ElementId viewIdToReference,
XYZ headPoint,
XYZ tailPoint
)
Public Shared Sub CreateReferenceSection (
document As Document,
parentViewId As ElementId,
viewIdToReference As ElementId,
headPoint As XYZ,
tailPoint As XYZ
)
public:
static void CreateReferenceSection(
Document^ document,
ElementId^ parentViewId,
ElementId^ viewIdToReference,
XYZ^ headPoint,
XYZ^ tailPoint
)
static member CreateReferenceSection :
document : Document *
parentViewId : ElementId *
viewIdToReference : ElementId *
headPoint : XYZ *
tailPoint : XYZ -> unit
Parameters
- document Document
-
The document to which the reference section will be added.
- parentViewId ElementId
-
The view in which the new reference section marker will appear.
Reference sections can be created in FloorPlan, CeilingPlan, StructuralPlan, Section, Elevation,
Drafting, and Detail views.
- viewIdToReference ElementId
-
Detail, Drafting and Section views can be referenced.
The ViewFamilyType of the referenced view will be used by the new reference section.
- headPoint XYZ
-
Determines the location of the section marker's head in the parent view.
- tailPoint XYZ
-
Determines the location of the section marker's tail in the parent view.
ExceptionsException | Condition |
---|
ArgumentException |
The ElementId viewIdToReference does not correspond to a View.
-or-
The ElementId parentViewId does not correspond to a View.
-or-
The parent view and the referenced view must be different views.
-or-
Can't create a new reference sections in parentViewId. Parent views must be
FloorPlan, CeilingPlan, StructuralPlan, Section, Elevation, Drafting, or Detail views.
-or-
The viewIdToReference cannot be referenced by reference sections. Only Detail, Drafting and Section views can be referenced.
-or-
headPoint and tailPoint do not differ when projected onto a plane perpendicular to the view direction.
-or-
Reference section view creation is not allowed in this family.
|
ArgumentNullException |
A non-optional argument was null
|
ModificationForbiddenException |
The document is in failure mode: an operation has failed,
and Revit requires the user to either cancel the operation
or fix the problem (usually by deleting certain elements).
-or-
The document is being loaded, or is in the midst of another
sensitive process.
|
ModificationOutsideTransactionException |
The document has no open transaction.
|
Remarks
The reference section will assume the ViewFamilyType of the view it references.
See Also