Provides a container of all Revit built-in FailureDefinitionId instances.
The BuiltInFailures..::..ConnectorFailures type exposes the following members.
Properties
| Name | Description | |
|---|---|---|
| AirTerminalCenterNotAligned |
The center of the Air Terminal doesn't align at (0,0,0): align the Air Terminal Center to the Origin Defining Reference Planes could help to solve the problem.
| |
| AllElementsRemovedFromCircuitGroup |
[System] is empty and will be deleted.
| |
| DisconnectedElements |
Elements are disconnected!
| |
| ElementAssignedToDefaultSystem |
At least one connector on the highlighted element is currently assigned to the [Element Name]. In general items shouldn't be assigned to the Default Systems, but should be assigned as equipments or elements of a non-default system. Click the More Info button below for additional information on System Creation.
| |
| ElementHasMultipleConnectors |
Revit found one or more elements with multiple connectors. Select each element and then select the connectors to use for the analytical connection.
| |
| ElementsAreDisconnected |
Elements need to be disconnected.
| |
| ElementsConnectedToParent |
You have selected elements that are connected to a parent object in a System. These elements cannot be removed from the System.
| |
| ElementsNeedToBeDisconnected |
Elements need to be disconnected.
| |
| ExistsForSelectedElement |
Connections already exists for selected element.
| |
| FittingMustBeOnDuct |
The [Tap] must be attached to duct.
| |
| FittingMustBeOnDuctWarn |
The [Tap] must be attached to duct.
| |
| FittingMustBeOnPipe |
The [Tap] must be attached to pipe.
| |
| FittingMustBeOnPipeWarn |
The [Tap] must be attached to pipe.
| |
| InvalidConnectionRef |
The selected fitting has invalid connections and must be deleted to continue.
| |
| InvalidConnector |
The connector is invalid, the size cannot be determined from the connector.
| |
| InvalidLoadClassificationValue |
The load classification parameter cannot be empty. Please select a valid load classification element for the connector parameter and the associated family parameter.
| |
| InvalidPowerFactorValue |
The value for Power Factor must be between 0 and 1.
| |
| JointGenderMismatch |
The element has a connector with a fitting joint gender mismatch
| |
| JointShapeMismatch |
The element has a connector with a fitting joint shape mismatch
| |
| JointSizeMismatch |
The element has a connector with a fitting joint size mismatch
| |
| JointTypeMismatch |
The element has a connector with a fitting joint type mismatch
| |
| LayoutConnector |
[Unassigned System Type] on Connector [Index Number].
| |
| MismatchNoAvailableConnector |
Cannot add [Element] to System. There is no available connector matching the System Type ([Type Name]) for the System.
| |
| MultipleNetwork |
Elements in [System Name] are not connected in a single physical network due to one or both of the following:\n- There are disconnects in the system's physical network.\n- Elements in the system are connected to more than one physical network.
| |
| NetworkValidityError |
The family is connected in a network and can no longer keep the connectivity. Disconnect the family from the network?
| |
| NetworkValidityErrorWasDisconnected |
The family is connected in a network and can no longer keep the connectivity. Disconnect the family from the network?
| |
| NoLossDefined |
No Loss Defined
| |
| NoSupportKCoefficientTable |
"K Coefficient from table" is not supported on connector for the element
| |
| NotAllowedToModifyGroupElementsError |
Connection to a group failed. Modification of elements within a group is not allowed.
| |
| NotAllowedToModifyGroupElementsWarning |
Connection to a group failed. Modification of elements within a group is not allowed.
| |
| OpenConnector |
The element has an open connector
| |
| RbsNetworkValidityError |
The family is connected in a network and can no longer keep the connectivity.
| |
| RemoveConnectorLinksWarn |
The links between connector [Index] and connector [Index], connector [Index] and connector [Index] are removed.
| |
| RemoveConnectorLinkWarn |
The link between connector [Index] and connector [Index] is removed.
| |
| ShapesNotMatch |
Shapes do not match. A connection could not be made.
| |
| SizingCalculationFlowOnlyWarn |
Some elements are not sized because the system calculation is flow only. You may change the system calculation level to size them again.
| |
| SizingCalculationNoneWarn |
Some elements are not sized because the system calculation level is none or performance. You may change the system calculation level to size them again.
| |
| SizingFailed |
Sizing failed.
| |
| UnconnectedCircuit |
The element has an unconnected circuit on its connector
| |
| UnconnectedDevice |
Device has an unconnected [Type Name] connector (index = [Index Number]).
| |
| UndefinedConnector |
Revit does not support Undefined connectors. The following have been replaced by the default connector: [Connector Element]
|