Constructs an object that stores the basic size information for conduit.
Namespace: Autodesk.Revit.DB.ElectricalAssembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntaxpublic ConduitSize(
double nominalDiameter,
double innerDiameter,
double outerDiameter,
double bendRadius,
bool usedInSizeLists,
bool usedInSizing
)
Public Sub New (
nominalDiameter As Double,
innerDiameter As Double,
outerDiameter As Double,
bendRadius As Double,
usedInSizeLists As Boolean,
usedInSizing As Boolean
)
public:
ConduitSize(
double nominalDiameter,
double innerDiameter,
double outerDiameter,
double bendRadius,
bool usedInSizeLists,
bool usedInSizing
)
new :
nominalDiameter : float *
innerDiameter : float *
outerDiameter : float *
bendRadius : float *
usedInSizeLists : bool *
usedInSizing : bool -> ConduitSize
Parameters
- nominalDiameter Double
-
Nominal diameter. The value should be a valid, positive Revit length.
- innerDiameter Double
-
Inner diameter. The value should be a valid, positive Revit length.
- outerDiameter Double
-
Outer diameter. The value should be a valid, positive Revit length.
- bendRadius Double
-
Minimum bend radius. The value should be a valid, positive Revit length.
- usedInSizeLists Boolean
-
Whether it is used in size lists.
- usedInSizing Boolean
-
Whether is used in sizing.
ExceptionsException | Condition |
---|
ArgumentOutOfRangeException |
The given value for nominalDiameter must be greater than 0 and no more than 30000 feet.
-or-
The given value for innerDiameter must be greater than 0 and no more than 30000 feet.
-or-
The given value for outerDiameter must be greater than 0 and no more than 30000 feet.
-or-
The given value for bendRadius must be greater than 0 and no more than 30000 feet.
|
See Also