ViewSystemsAnalysisReportCreate Method

Creates a new view for the systems analysis report.

Namespace: Autodesk.Revit.DB.Analysis
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public static ViewSystemsAnalysisReport Create(
	Document document,
	string viewName
)

Parameters

document  Document
The document where the view is to be created.
viewName  String
The name of the new report view.

Return Value

ViewSystemsAnalysisReport
The newly created view instance, or if the operation fails.
Exceptions
ExceptionCondition
ArgumentException viewName cannot include prohibited characters, such as "{, }, [, ], |, ;, less-than sign, greater-than sign, ?, `, ~". -or- viewName is an empty string.
ArgumentNullException A non-optional argument was null
InvalidOperationException The document is in failure mode: an operation has failed, and Revit requires the user to either cancel the operation or fix the problem (usually by deleting certain elements).
ModificationForbiddenException The document is in failure mode: an operation has failed, and Revit requires the user to either cancel the operation or fix the problem (usually by deleting certain elements). -or- The document is being loaded, or is in the midst of another sensitive process.
ModificationOutsideTransactionException The document has no open transaction.
Remarks
A report instance is typically created to request a new systems analysis. The default values include the weather file "USA_CO_Denver.Intl.AP.725650_TMY3.epw" and the workflow file "HVAC Systems Loads and Sizing.osw". Both are part of the Revit installation. The default output folder is the system TEMP folder.
See Also