Provides a container of all Revit built-in FailureDefinitionId instances.

The BuiltInFailures..::..RoofFailures type exposes the following members.

Properties

  NameDescription
Public propertyStatic memberCurveRoofSkippedLoops
Some loops were skipped
Public propertyStatic memberCurveRoofSkippedLoopsError
Some loops were skipped
Public propertyStatic memberCurveRoofSkippedLoopsWarn
Some loops were skipped
Public propertyStatic memberExtrudedRoofCutBySketch
Entire extruded Roof is cut by cut Sketch.
Public propertyStatic memberHadToAlignEaves
Adjacent slope-defining lines must have identical eave heights. Eaves were aligned to higher location automatically to avoid failure. Use the Align Eaves tool to specify desired location.
Public propertyStatic memberHoleInRoofFailed
Hole(s) could not be cut in roof.
Public propertyStatic memberInvalidArcSegmentation
A segmented slope-defining arc has too few segments.
Public propertyStatic memberJoinedRoofMissesTarget
Part of the roof to be joined misses the target face.
Public propertyStatic memberJoinedRoofMissesTargetError
Part of the roof to be joined misses the target face.
Public propertyStatic memberNoFlatCurtainRoofs
A Sloped Glazing with no slope is not allowed.
Public propertyStatic memberOnlyOneSlopeCurtainRoof
Only one slope in curtain roof.
Public propertyStatic memberOnlyUpwardFacesUsed
The selected faces contain both upward and downward pointing faces. Only the upward pointing faces were used.
Public propertyStatic memberRoofCutoffRemoved
The roof's cutoff failed and was removed; make sure the cutoff height is not below the roof.
Public propertyStatic memberRoofExceedsMaxHeight
Roof exceeds user-specified maximum height
Public propertyStatic memberRoofMeetsRoofTangentially
The roofs cannot be joined because the roof being joined meets the target roof tangentially.
Public propertyStatic memberRoofMeetsRoofTangentiallyError
The roofs cannot be joined because the roof being joined meets the target roof tangentially.
Public propertyStatic memberRoofSlopeExceedsThreshold
Thickness of this Roof may be slightly inaccurate due to extreme Shape Editing. Dimensions to this element in sections and details may not accurately indicate the Thickness shown in Type Properties.
Public propertyStatic memberRoofToRefPlanes
Roof cannot be joined to more than one reference plane.
Public propertyStatic memberRoofToRefPlanesError
Roof cannot be joined to more than one reference plane.
Public propertyStatic memberUnusedSlopeArrow
The tails of all slope arrows must lie on the roof boundary.
Public propertyStatic memberUptoHeightTooLow
Cutoff Level cannot be below bottom of roof.
Public propertyStatic memberUserCancelledRoof
Cancelled.
Public propertyStatic memberWorkplaneShouldBeLevel
Can't use Workplane that is not a Level. Set the desired Level as current Workplane.

See Also