Switches the circuit phases at the slot.

Namespace: Autodesk.Revit.DB.Electrical
Assembly: RevitAPI (in RevitAPI.dll) Version: 21.0.0.0 (21.1.1.109)
Since:  2021

Syntax

C#
public void SwitchPhases(
	int nRow,
	int nCol
)
Visual Basic
Public Sub SwitchPhases ( _
	nRow As Integer, _
	nCol As Integer _
)
Visual C++
public:
void SwitchPhases(
	int nRow, 
	int nCol
)

Parameters

nRow
Type: System..::..Int32
Row Number.
nCol
Type: System..::..Int32
Column Number.

Remarks

Only one or two poles circuit on switchboard panel schedule can switch phases.

Exceptions

ExceptionCondition
Autodesk.Revit.Exceptions..::..ArgumentException The circuit at given cell (nRow, nCol) is not one or two poles circuit.
Autodesk.Revit.Exceptions..::..ArgumentOutOfRangeException The given row number nRow is invalid in Body. -or- The given column number nCol is invalid in Body. -or- There is no circuit at given cell (nRow, nCol).
Autodesk.Revit.Exceptions..::..InvalidOperationException This is not a switchboard panel schedule.

See Also