Creates new system which is hydraulically separated from the existing system.
Namespace: Autodesk.Revit.DB.PlumbingAssembly: RevitAPI (in RevitAPI.dll) Version: 21.0.0.0 (21.1.1.109)
Since: 2019
Syntax
C# |
---|
public static ISet<ElementId> CreateHydraulicSeparation( Document document, ISet<ElementId> pipeElementIds ) |
Visual Basic |
---|
Public Shared Function CreateHydraulicSeparation ( _ document As Document, _ pipeElementIds As ISet(Of ElementId) _ ) As ISet(Of ElementId) |
Visual C++ |
---|
public: static ISet<ElementId^>^ CreateHydraulicSeparation( Document^ document, ISet<ElementId^>^ pipeElementIds ) |
Parameters
- document
- Type: Autodesk.Revit.DB..::..Document
The document where the new system is created.
- pipeElementIds
- Type: System.Collections.Generic..::..ISet<(Of <(<'ElementId>)>)>
The boundary pipe that defines a new system. Multiple pipes are allowed to create more than one separated systems.
Return Value
The newly created piping system elements.
Remarks
Hydraulically separated systems allow independent flow and pressure analysis for each hydraulic loop.
For example, each hydraulic loop has its own cirtical path. The calculated pressure drop on the primary
pump is consisted of all pressure drop on the primary critical path. Any pressure drop on the secondary
loop would only contribute to the calculated pressure drop of the secondary pump.