Provides a container of all Revit built-in FailureDefinitionId instances.
The BuiltInFailures..::..RebarSystemFailures type exposes the following members.
Properties
| Name | Description | |
|---|---|---|
| AreaReinforcementOutSideOfHost |
Area Reinforcement is sketched completely outside of its host.
| |
| AreaReinforcementRegenFail |
Can't regenerate Area Reinforcement.
| |
| AreaReinforcementsCollision |
Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision.
| |
| AreaReinforcementWrongHost |
Area Reinforcement can be placed only in Structural Floors and straight Structural Walls.
| |
| BarsTooCloseNumber |
Bars are too close together. Decrease the Number Of Lines parameter.
| |
| BarsTooCloseSpacing |
Bars are too close together. Increase the Maximum Spacing parameter.
| |
| BarsTooSparseSpacing |
Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter.
| |
| CannotPlaceAreaReinforcement |
Can't find a host for Area Reinforcement.
| |
| CannotPlaceAreaReinforcementWarn |
Can't find a host for Area Reinforcement.
| |
| CannotPlaceAreaReininforcement |
Can't find a host for Area Reinforcement.
| |
| CannotPlaceAreaReininforcementWarn |
Can't find a host for Area Reinforcement.
| |
| CannotPlacePathReinforcement |
Can't find a host for Path Reinforcement.
| |
| CannotPlacePathReinforcementWarn |
Can't find a host for Path Reinforcement.
| |
| CannotPlacePathReininforcement |
Can't find a host for Path Reinforcement.
| |
| CannotPlacePathReininforcementWarn |
Can't find a host for Path Reinforcement.
| |
| CannotUseAreaReinforcementHookTypeStyle |
At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
| |
| CannotUsePathReinforcementHookTypeStyle |
At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
| |
| DPartReinfDeletedEditDivision |
Edits to the model will cause some Reinforcement hosted on Parts to be deleted.
| |
| DPartReinforcementDeleted |
Reinforcement hosted on highlighted Parts will be deleted.
| |
| HostFlagAreaOff | ||
| HostFlagAreaOn |
The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off.
| |
| HostFlagPathOff | ||
| HostFlagPathOn | ||
| PathReinforcementWrongHost |
Path Reinforcement can be placed only in Structural Floors and straight Structural Walls.
| |
| RebarSystemOffset |
Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate.
| |
| ThinHostFloor |
Rebar Cover Top and Bottom are too large for host.
| |
| ThinHostFloorError |
Rebar Cover Top and Bottom are too large for host.
| |
| ThinHostWall |
Rebar Cover Interior and Exterior are too large for host.
| |
| ThinHostWallError |
Rebar Cover Interior and Exterior are too large for host.
|